TTK Heat Setting Workshop runs 3 Monforts stenters and a 31-chamber oven, focused on low-tension heat setting. We handle stenter setting, after-setting, heat setting and setting of customer-supplied fabric.
Standardized production workshop · Continuous line of the heat-setting section
Heat setting is a physical finishing process. Once a fabric has been coated or laminated, the temperature window of the coating and film, the softening point of the hot-melt adhesive and the elastic recovery of the base fabric together determine the temperature and tension this step can use. We set the process from the incoming material system rather than running every fabric on one set of parameters.
The equipment is built around low-tension setting and handles knitted, woven and stretch fabrics. For stretch fabric the question is how much elastic recovery is retained; for high-density woven fabric it is whether the width holds. When tension is too high, these are the first two to fail.
Heating is by steam: stable temperature and even heat, avoiding the hardening and shade change caused by local overheating. The line has oil-free rails and a photoelectric weft straightener — the former lowers the risk of oil marks on the fabric, the latter detects weft skew online and reduces the variation of manual correction.
Besides setting itself, the workshop also has a rotary-spray single-side machine for single-side repellent / single-side absorbent finishing, and it can top up water repellency after lamination or coating. We take both setting and functional finishing of customer-supplied fabric, and setting alone can also be ordered as a single process.
| — | — |
|---|---|
| Stenters | 3 × Monforts stenters, each with independent chamber temperature control |
| Oven chambers | 1 × 11 chambers + 2 × 10 chambers, 31 chambers in total |
| Max. width | 175 cm |
| Capacity per stenter | 50,000–80,000 m/day |
| Total capacity | approx. 150,000–240,000 m/day, varying by article |
| Accepted incoming fabric | Fabric already finished with PU, PA, solvent-free PU/PUR or PVC coating, plus laminated and printed fabric |
| Order mode | Full order or single process |
Indicative, not to scale; maximum working width 175 cm
Equipment & process
Stable temperature, even heat; less hardening and shade change from local overheating
Lower risk of oil marks on the fabric
Detects skew online and reduces the variation of manual correction
Pins arranged and calibrated; hard pin marks and pin bars are less likely
Maximum working width 175 cm, tolerance within ±0.5 cm; measured online and recorded every 300 yards.
Internal standard is ≤±1.0% warp and weft; the reported figure follows the corresponding test report.
A photoelectric skew corrector detects and corrects online; the exit is also checked visually to reduce the variation of manual correction.
Water-repellent routes: both fluorine-free (C0) and fluorinated C6/C8 are available, selected per customer requirement and restricted-substance list.
Certifications (11 items)
Testing
Testing is handled by the TTK Test Centre. It is our in-house laboratory, covering in-process and final inspection with a testing view independent of the production line; when an external institution's report is needed, we can arrange submission and help verify it.
Sampling, minimum order and lead time are all confirmed on the order, with peak-season dates against the confirmed sheet.
Request a Sample →Knitted, woven and stretch fabrics, with or without elastane. Low tension suits stretch-sensitive fabric: it is how elastic recovery and hand feel are kept.
Steam keeps the temperature stable and heats the fabric evenly, so local overheating does not harden the fabric or change its shade.
They lower the risk of oil marks. Rails that need lubrication leave marks on light shades and on high-end orders; oil-free rails remove that source at the machine.
The pins are arranged and calibrated, so hard pin marks and pin bars are less likely, and the selvedge stays neat.
A photoelectric skew corrector detects and corrects online, with a visual check at the exit, reducing the variation of manual correction.
Three Monforts lines: 11 dryer chambers on one, 10 on each of the other two, 31 in total, each with independently controlled sections.
From the temperature limits of the fibre and the finishing agents, not as a fixed value. Polyester usually sets at 180–190 °C; coated and laminated fabric is set lower, within the coating and agent limits, so neither is damaged.
Their temperature limits set the range. PA takes a higher range for full setting; PU needs a capped temperature to protect the micro-phase structure and hand feel; solvent-free PU balances cure and setting.
Yes; we process the finished PVC-coated fabric as incoming material. PVC-coated fabric is usually made by calendering at around 160–185 °C, so it enters setting at a low temperature to prevent plasticiser migration, tackiness and shrinkage. The exact temperature follows the incoming state, set at process review.
When temperature matches the adhesive's softening point and tension stays low, the laminate holds. Coating cracking and separation come from too high a temperature or too much tension.
Maximum working width 175 cm; normal widths are set per order, with tolerance within ±0.5 cm.
Three stenters at 50,000–80,000 m/day each, about 150,000–240,000 m/day in total; actual capacity varies with article, width and process complexity.
27: three-proof, fluorine-free (C0) water repellency, single-side repellency and absorbency, antibacterial, anti-mould, flame retardant, UV protection, far infrared, cool touch, moisture wicking, fragrance, anti-wrinkle, anti-static, easy-clean, anti-pilling, down-proof, windproof, water repellent, hydrophilic, oil repellent, anti-mite, insect repellent, mothproof, negative ion, thermal / heat storage, vitamin A skin care and collagen skin care.
Sampling first. The rotary-spray machine tops up repellency by controlled spraying and brings part of it back; whether it applies depends on the fabric state and the following processes.
Water repellent on one face, hydrophilic on the other: the face repels, the back absorbs, common in sportswear and outdoor fabric for one-way moisture transport.
It raises peel strength on laminated fabric and supports combinations such as repellency after lamination or after coating.
Per the workshop's process documents, 100 washes.
We run both routes: fluorine-free (C0) and fluorinated C6/C8. The choice follows the customer's requirement, end use and restricted-substance list; specific substances follow the customer's RSL and test reports.
Functional substances encapsulated and released slowly for longer effect, such as microcapsule heat storage, fragrance and cool-touch microcapsules.
Normally within ±0.5 cm, measured online and recorded every 300 yards; tighter requirements can be agreed at process review.
Internal target is ≤±1.0% warp and weft; the reported figure follows the corresponding test report.
Oil-free rails and calibrated pins reduce both at the machine, and the process is recorded end to end so a defect can be traced to coating, lamination or setting.
Certifications (11 items, names only): ISO 9001, ISO 14001, ISO 45001, GJB 9001C-2017, GRS, RCS, OEKO-TEX® STANDARD 100, HIGG FEM, HIGG FSLM, RWS; also a bluesign® SYSTEM PARTNER. Testing is handled by the TTK Test Centre, our in-house laboratory, for in-process and final inspection; when an external institution's report is needed, we can arrange submission and help verify it.
Yes, for setting and functional finishing. Incoming material is inspected first to confirm it suits setting.
Sampling in 1 day: scheduled the same day after the process is confirmed, with sample and test data the next day. Minimum order 500 m; below that, use the sampling route. Standard lead time 1–5 days, longer for multi-step coating and lamination combinations. Sampling, minimum order and lead time are all confirmed on the order, with peak-season dates against the confirmed sheet.